Inserting a CAD File as an XReference Into a TPC Drawing

 

 

 

 

Beginning with TPC Desktop 2018, we recommend that you consider inserting the drawing as an XReference instead of importing it into your drawing. 

 

See Using Xreferences.

 

CAD: Import XReference (8:41) - Learn how to import a CAD drawing as an XReference


Common Workflows

•You've received a CAD file for a project

•You've opened that file in the CAD View and determined they sent you just the layers and entities you need

•Your easiest option is to insert the entire CAD file into your TPC drawing as an XReference


Inserting a one-off  XReference without Calibration to a TPC Drawing

With TPC, you

•Insert the CAD file as an XReference

•Check some of the CAD positions against your survey positions to see if you need to calibrate it

•If the XReference checks out, there is no need to calibrate and you are ready to go

See Using Xreferences.


Inserting a one-off  XReference with Calibration to a TPC Drawing

If you insert an XReference and it doesn't fit your survey, you can calibrate it.

See Calibrating XReferences.


Getting Revised CAD Files for XReferences

One of the benefits of using XReferences in your drawing, is that they automatically update themselves when their associated CAD file changes.

This all depends on how the project manager updates CAD files. 

•Sometimes revisions are made to an existing CAD file that simply has a new modified date.

•Sometimes revisions are made to copies of a CAD file that new file names.

These options affect how you interact with the files in TPC.

If you get a revision of the associated CAD file

•If you get a newer version of the same file name, the XReference re-loads the CAD file, updating the XReference automatically. 

•If you calibrated the XReference, it will continue to calibrate the associated CAD file just as you would expect it it.

 

If you get a revision as a new CAD file

If the next CAD file you get is not the same filename, you will need to do the following steps

1.Edit the calibration the XReference is using and add the new CAD file path and name as a referenced file.

2.Delete the existing XReference if you no longer need it.  But you can leave it in also.

3.Insert an XReference for the new, revised CAD file.  It should automatically calibrate since it is now associated with a calibration.