TPC 2026
TPC 2026

 

 

Navigation: Adjusting a Traverse >

Applying Curvature and Refraction command

 

 

 

 

When correcting a traverse for curvature and refraction, TPC applies the curvature and refraction correction to each control point following the Initial point up to and including the Closing point. The Initial point itself is not affected by this correction. Side shots are also adjusted. TPC even applies C&R to benchmark observations in order to compute a more accurate height of instrument equivalent.

 

Curvature And Refraction (1:31) - Adjust a ground traverse for curvature and refraction


Equations

TPC uses the following equations to adjust for C&R:

HD = (SD*SIN(ZA)) - [(1-(0.5*COEF)) / RADIUS * (SD*COS(ZA)) * (SD*SIN(ZA))]

VD = (SD*COS(ZA)) + [(1-COEF) / (2*RADIUS) * (SD*SIN(ZA)) * (SD*SIN(ZA))]

Where:

HD= computed horizontal distance

VD= computed vertical distance

SD= measured slope distance

ZA= measured zenith angle

COEF= 0.13 = est. coefficient of refraction

RADIUS= 20,906,000 ft or 6,372,200 m = estimated radius of the earth

Although these equations do not incorporate height of instrument in the radius, they give very good estimates under typical conditions.

TPC will not apply this adjustment if raw data does not exist.


Sticky Adjustment

TPC refers to Precision, Curvature & Refraction and Scale Factor as 'sticky' adjustments. You can apply sticky adjustments before balancing angles and coordinates. Sticky adjustments also remain in effect when you choose Tools | Recompute from the Traverse View.


Related Topics

Checking Traverse Closure
Closure View
Adjusting a Traverse
Sticky Adjustments

Editions

Premium, Professional

 

 

 

Copyright © 2026 Traverse PC, Inc.