Repetition sets use the lower motion tangent screw or the hold button on the total station to turn the total station without changing the horizontal circle reading. The sequence of shots in a repetition set is important and always involves sighting the backsight with the lower motion and sighting the foresight with the upper motion.
TPC allows two different repetition sets. Using the letters B for backsight and F for foresight, they are BF2 and BF4.
BF2
This is a STANDARD "Repeat Angle" set in which the inverted backsight is not recorded. Since the gun is inverted and turned to the backsight using the lower motion, the horizontal circle reading does not change from the first foresight to the second backsight. With this assumption, the second backsight is not recorded. Your total station must have a lower motion tangent screw or a hold button to use this method. The sequence is:
•Enter the backsight circle reading for the BS or B1 record, (you do not need to zero the gun on the backsight but most people do). Release the upper motion on your instrument and turn to the foresight F1.
•Enter the foresight data for the F1 record, lock the upper motion, release the lower motion, invert or plunge the scope, and turn again to your backsight.
•Rotate the scope to your foresight with the scope in the inverted position.
•Record your data, (F2). TPC will compute a mean for the horizontal angle based on the recorded horizontal circle readings. If you have also recorded an inverted vertical circle reading, it will mean those. Recorded distances will also be mean. Recording a vertical circle reading and a second distance is optional.
|
Point
|
Type
|
Data
|
|
1
|
|
|
|
2
|
BS
|
|
|
3
|
F1
|
|
|
3
|
F2
|
|
|
3
|
FSM
|
|
In the example shown here, the BS record contains the B1 data, so B2 is not needed. Most of us who have been surveying for more than 20 years will remember this a doubling angles and we did this because it was easy to figure a mean without a calculator.
BF4
This is a STANDARD "Repeat Angle" set in which the inverted backsight is not recorded and the foresight angle is repeated four times before being recorded. This is referred to as “cranking the angles four times”. The sequence is:
|
Point
|
Type
|
Data
|
|
1
|
|
|
|
2
|
BS
|
|
|
3
|
F1
|
|
|
3
|
F4
|
|
|
3
|
FSM
|
|
•Record the horizontal circle reading for the BS or B1 record, (you do not need to zero the gun on the backsight but most people do). Release the upper motion and turn the scope to the foresight, F1.
•Record the data for your shot to the foresight F1. Lock the upper motion and release the lower motion and invert the scope and re-sight the backsight. Repeat this process until you have completed four cycles. Notice that each time you re-sight the backsight the scope is plunged.
•In this sequence, the final shot to the foresight will be with the scope in the inverted position. Record your data after sighting the foresight for the fourth time (F4).
TPC will compute a mean for the horizontal angle based on the recorded horizontal circle readings. If you have also recorded an inverted vertical circle reading, it will mean those. Recorded distances will also be mean. Recording a vertical circle reading and a second distance is optional.
Related Topics
Traverse View Entering Traverse Data Entering Side Shots Displaying Raw Data Recomputing a Traverse Entering a Set
Editions
Premium, Professional
|